Reference No. : 54120801G                                                                                                                        Page 14
 
◀  Anam EMC Test Laboratory  ▶
 
 
8.5. Test protocols 
 
Date: December 18, 2007 
 
The equipment does comply with the requirements. Operating condition: The   
 
EUT continuously operated with audio frequency of 1,000 ㎐ color bar being 
 
supplied from the Oscillator or test DVD. An absorbing clamp was placed 
 
around all leads. At each mode, the maximum value at each testing frequency 
 
and each output lead was registered and attached as follows. 
Limit(㏈㎺) Result(㏈㎺) 
Test Lead 
Freq. 
(㎒) 
QP AV QP  AV 
PHONO 126.28 
48.6 38.6 31.4  30.4 
TAPE IN 
126.28 
48.6 38.6 30.4  29.5 
TAPE OUT 
126.28 
48.6 38.6 30.5  30.5 
VID1 IN 
126.28 
48.6 38.6 30.6  30.4 
VID 1 OUT 
126.28 
48.6 38.6 31.3  30.3 
VID 2 
126.28 
48.6 38.6 32.1  31.2 
VID 3 
126.28 
48.6 38.6 30.3  30.0 
VID 1 IN/OUT 
126.28 
48.6 38.6 30.5  30.3 
VID 2,3,MONITOR 
126.28 
48.6 38.6 30.2  30.1 
REMOTE IN 
126.28 
48.6 38.6 30.9  30.6 
REMOTE OUT 
126.28 
48.6 38.6 30.5  30.2 
TRIGGER 1 
80.00 
46.8 
36.8 
28.9 
27.7 
TRIGGER 2 
80.00 
46.8 
36.8 
28.8 
27.5 
SUB OUT 
126.28 
48.6 38.6  * 
SPEAKER 1 L 
126.28 
48.6 38.6  * 
SPEAKER 1 R 
126.28 
48.6 38.6  * 
SPEAKER 2 L 
126.28 
48.6 38.6  * 
SPEAKER 2 R 
126.28 
48.6 38.6  * 
PHONES 126.28 
48.6 38.6 35.4  35.1 
FRONT AUDIO, VIDEO  126.28 
48.6 38.6 25.5  * 
AC POWER CORD 
126.28 
48.6 38.6  * 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 