Read Harman Kardon HK 3390 (serv.man2) EMC - CB Certificate online
Reference No. : 54120801G Page 14
◀ Anam EMC Test Laboratory ▶
8.5. Test protocols
Date: December 18, 2007
The equipment does comply with the requirements. Operating condition: The
EUT continuously operated with audio frequency of 1,000 ㎐ color bar being
supplied from the Oscillator or test DVD. An absorbing clamp was placed
around all leads. At each mode, the maximum value at each testing frequency
and each output lead was registered and attached as follows.
Limit(㏈㎺) Result(㏈㎺)
Test Lead
Freq.
(㎒)
QP AV QP AV
PHONO 126.28
48.6 38.6 31.4 30.4
TAPE IN
126.28
48.6 38.6 30.4 29.5
TAPE OUT
126.28
48.6 38.6 30.5 30.5
VID1 IN
126.28
48.6 38.6 30.6 30.4
VID 1 OUT
126.28
48.6 38.6 31.3 30.3
VID 2
126.28
48.6 38.6 32.1 31.2
VID 3
126.28
48.6 38.6 30.3 30.0
VID 1 IN/OUT
126.28
48.6 38.6 30.5 30.3
VID 2,3,MONITOR
126.28
48.6 38.6 30.2 30.1
REMOTE IN
126.28
48.6 38.6 30.9 30.6
REMOTE OUT
126.28
48.6 38.6 30.5 30.2
TRIGGER 1
80.00
46.8
36.8
28.9
27.7
TRIGGER 2
80.00
46.8
36.8
28.8
27.5
SUB OUT
126.28
48.6 38.6 *
*
SPEAKER 1 L
126.28
48.6 38.6 *
*
SPEAKER 1 R
126.28
48.6 38.6 *
*
SPEAKER 2 L
126.28
48.6 38.6 *
*
SPEAKER 2 R
126.28
48.6 38.6 *
*
PHONES 126.28
48.6 38.6 35.4 35.1
FRONT AUDIO, VIDEO 126.28
48.6 38.6 25.5 *
AC POWER CORD
126.28
48.6 38.6 *
*
Click on the first or last page to see other HK 3390 (serv.man2) service manuals if exist.