HK 3380 (serv.man10) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 30

Read Harman Kardon HK 3380 (serv.man10) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 25 of 37 - 
 
 
   
 Order 
No. 
14649
 
 
 
 
 
Permanently connected apparatus 
and apparatus with non-detachable 
mains cord provided with separate 
protective earth terminal near mains 
input  
 
 
Protective earth connection of a part 
removable by hand. 
 
 
Protective earth terminal resistant to 
corrosion  
 
 
Earth resistance (
) test: 
 0,1 
 at 
25 A      
 
15.3. 
Terminals for external flexible cords 
and for permanent connection to the 
mains supply
 
 
15.3.1 
Adequate terminals for connection of 
permanent wiring   
Apparatus is not for permanent connection. 
15.3.2 
Reliable connection of non-
detachable cords: 
 
 
 
Connection of the non-detachable 
cord 
Connected with a two-pole connector 
 
Soldered to conductors of a printed 
circuit board   
No 
 
Adequate clearances and creepage 
distances between connections 
should a wire break away   
Wires are clamped two times to the contact terminal and 
provided with a two-pole connector 
 
Wire secured by additional means   
Adequately anchored. Tested with 5 N. 
 
15.3.3 
Screws and nuts clamping external 
mains supply conductors have 
adequate threads: ISO 261, ISO 262 
or similar   
No screws and nuts clamping   
15.3.4 
Soldered conductors wrapped 
around terminal prior to soldering or 
held in place by additional means   
No soldered conductors 
 
Clamping of conductor and 
insulation if not soldered or held by 
screws  
Clamped the insulators and conductors
 
15.3.5 
Terminals for external flexible cords 
shall allow connection of appropriate 
cross-sectional area of conductors 
for the rated current of the 
equipment  
Terminals have adequate connection capacity.   
15.3.6 
Terminals to 15.3.3 have sizes 
required by Table 8   
 
Page of 49