Read Harman Kardon HD 990 (serv.man5) EMC - CB Certificate online
Test report no. SH08090332-001
Page 64 of 76
17.4 Test Protocol
Temperature :
22
°C
Relative Humidity: 46%
Test no.:
Test no.:
Frequency
(MHz)
(MHz)
Polarization Test
level
V/m
Exposed
location
location
Result Comment
1
900
H & V
3
All sides
Pass
-
17.5 Measurement Uncertainty
The measurement uncertainty describes the overall uncertainty of the given measured
value during the operation of the EUT.
Measurement uncertainty of radiated susceptibility test is:
value during the operation of the EUT.
Measurement uncertainty of radiated susceptibility test is:
± 4.65dB
The measurement uncertainty is given with a confidence of 95%, k=2.
The measurement uncertainty is traceable to internal procedure TI-036.
The measurement uncertainty is traceable to internal procedure TI-036.
17.6 Additions, deviations and exclusions from standards
None