Read Harman Kardon HD 990 (serv.man3) EMC - CB Certificate online
Page 6 of 55 Report No. SH08090331-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Pass
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Pass
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
TR1 Pass
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
CY1, CY2, CY3
Pass
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No such voltage
N/A
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
N/A
Separation by Class II isolating transformer
N/A
Separation by Class I transformer
N/A
Separation by earthed conductive part
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) .................... : TR1 bobbin: 0.8mm min.
Optocoupler PH1:0.40mm min.
Enclosure (front panel): 1.5mm
min.
min.
Separation sheet on internal
enclosure under power board:
0.4mm min.
enclosure under power board:
0.4mm min.
Pass
Thin sheet insulation
Inside TR1.
Pass
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
Withstand 2120Vp test.
Pass
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A