Test report no. SH08050534-001 
 
 
Page 60 of 67 
 
18.3 Test Setup and Test Procedure 
 
Measurement was performed in shielded room. 
Instruments used were following CISPR 16-1 and EN 55020. 
Measurement methods and operation conditions of EUT was according to clause 5.1, 
5.2 and 5.6 of EN55020. 
 
 
18.4 Test Protocol 
 
Temperature  
22
°C  
Relative Humidity: 
40% 
 
Test No. 
Level 
[kV] 
Polarity 
+/- 
Line for test 
Pass/ 
Fail 
1 1 +/- 
a.c. 
Mains 
Pass 
2 X +/- 
NA 
Notes: “NA” means not applicable.  
“X” is for other availiable lines. 
 
Observation: The apparatus shall continue to operate as intended after the test.
 
 
Conclusion: The EUT met the requirements of Performance B 
 
 
 
18.5 Measurement Uncertainty 
 
The measurement uncertainty describes the overall uncertainty of the given measured  
value during the operation of the EUT. 
Measurement uncertainty of EFT test at main terminal is: 
± 18% 
Measurement uncertainty of EFT test at signal/telecom terminal is: 
± 18% 
The measurement uncertainty is given with a confidence of 95%, k=2. 
The measurement uncertainty is traceable to internal procedure TI-036. 
 
 
18.6 Additions, Deviations and Exclusions from Standards 
 
 
None
 
 
 
 
 
 