Read Harman Kardon HD 980 (serv.man4) EMC - CB Certificate online
Test report no. SH08050534-001
Page 14 of 67
4.3 Test Setup and Test Procedure
Measurement was performed in shielded room.
Instruments used were following CISPR 16-1.
Measurement methods and operation conditions of EUT was according to clause 5.2
Instruments used were following CISPR 16-1.
Measurement methods and operation conditions of EUT was according to clause 5.2
and 5.4 of EN55013
4.4 Test Protocol
Dis. source
(oscillator)
Dis. source
(oscillator)
Cha
n
n
el
Harm.
No.
Freq.
(MHz)
Test
result
(dB
µV)
Cha
n
n
el
Harm.
No.
Freq.
(MHz)
Test
result
(dB
µV)
Limits of
Standard
Standard
Fund.
94.15
Fund.
242.15
2
188.30
2
484.30
3
282.45
3
726.45
4
376.60
4
968.60
5
470.75
5
1210.75
6
564.90
6
1452.90
7
659.05
7
1695.05
8
753.20
10
8
1937.20
9
847.35
Fund.
542.15
10
941.50
2
1082.30
11
1035.65
25
3
1626.45
12
1129.80
Fund.
782.15
13
1223.95
55
2
1562.45
14
1318.10
15
1412.25
16
1506.40
17
1600.55
18
1694.70
19
1788.85
20
1883.00
21
1977.15
2
22
2071.30
OTHER
30
-2150
MHZ
TV set work
between
30MHz—
1000Mhz:
Oscillator:
Fundamental:
between
30MHz—
1000Mhz:
Oscillator:
Fundamental:
46
dBμ V
Harmonic:30MH
z—950MHz
46
dBµV
950MHz—
2150MHz
2150MHz
54
dBµV
others:
30MHz—
2150MHz
30MHz—
2150MHz
46
dBµV
Click on the first or last page to see other HD 980 (serv.man4) service manuals if exist.