Page 17 of 57 Report No. SH08050531-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
2 x 0.75mm
2
Pass
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N/A
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N/A
16.5
Adequate strain relief on external flexible cords
Strain relief bushing
Pass
Not possible to push cord back into equipment
Pass
Strain relief device unlikely to damage flexible cord
Pass
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
Pass
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
17 ELECTRICAL
CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to table 20:
Pass
- screws into metal: 5 times
Cover fixed
Pass
- screws into non-metallic material: 10 times
Cover fixed
Pass
17.2
Correct introduction into female threads in non-
metallic material
metallic material
N/A
17.3
Cover fixing screws: captive
N/A