Prüfbericht - Nr.:
Test Report No.:
15036107 001
Seite 9 von 33
Page 9 of 33
4.3
Mains Terminal Continuous Disturbance Voltage
Result:
Passed
Date of testing
: 25.01.2010
Test procedure
: EN 55013:2001+A1+A2 and CISPR 16-1 series
standards
Frequency range
: 0.15 – 30MHz
Bandwidth of EMI receiver :
9kHz
Detector
:
Peak, quasi-peak, average
Final measurement time
:
1s
Kind of test site
: Shielded room
Input voltage
: AC 230V, 50Hz
Ambient Condition
: Temperature: 16
o
C; Relative Humidity: 60%
The measurement setup was made according to EN 55013:2001+A1+A2 in a shielded room.
The measurement equipment like test receivers, quasi-peak detector and artificial mains
network (AMN) are in compliance with CISPR 16-1 series standards.
network (AMN) are in compliance with CISPR 16-1 series standards.
The tested object was set-up on a wooden table. The EUT was set 0.8m away from the
AMN. The cord longer than necessary to be connected to the AMN was folded forth and
back parallel so as to form a bundle with a length between 0.3m and 0.4m.
AMN. The cord longer than necessary to be connected to the AMN was folded forth and
back parallel so as to form a bundle with a length between 0.3m and 0.4m.
The disturbance voltage was determined according to clause 5.3 of EN 55013:2001+A1+A2
while measuring the line and neutral conductor by turns.
while measuring the line and neutral conductor by turns.
The following figures and tables were those measured by an automatic measuring system.
Both quasi-peak and average measurements were performed. In the following spectral
diagram, “x” means quasi-peak test results and “+” means average test results.
Both quasi-peak and average measurements were performed. In the following spectral
diagram, “x” means quasi-peak test results and “+” means average test results.