GO PLAY MICRO (serv.man6) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 9

Read Harman Kardon GO PLAY MICRO (serv.man6) EMC - CB Certificate online

 
 
 
Produkte 
Products
 
 
 
 
 
Prüfbericht - Nr.:
 
Test Report No.:
 
15036107 001
 
Seite 9 von 33 
Page 9 of 33 
 
 
 
4.3
 
Mains Terminal Continuous Disturbance Voltage 
Result: 
     Passed 
 
Date of testing 
:   25.01.2010 
Test procedure 
:   EN 55013:2001+A1+A2 and CISPR 16-1 series   
 standards 
Frequency range 
:   0.15 – 30MHz 
Bandwidth of EMI receiver  
9kHz 
Detector 
Peak, quasi-peak, average 
Final measurement time 
1s 
Kind of test site 
:   Shielded room 
Input voltage 
:   AC 230V, 50Hz 
Ambient Condition 
:  Temperature: 16
o
C; Relative Humidity: 60% 
 
The measurement setup was made according to EN 55013:2001+A1+A2 in a shielded room. 
The  measurement  equipment  like  test  receivers,  quasi-peak  detector  and  artificial  mains 
network (AMN) are in compliance with CISPR 16-1 series standards.  
The  tested  object  was  set-up  on  a  wooden  table.  The  EUT  was  set  0.8m  away  from  the 
AMN.  The  cord  longer  than  necessary  to  be  connected  to  the  AMN  was  folded  forth  and 
back parallel so as to form a bundle with a length between 0.3m and 0.4m.  
The disturbance voltage was determined according to clause 5.3 of EN 55013:2001+A1+A2 
while measuring the line and neutral conductor by turns.  
 
The  following  figures  and  tables  were  those  measured  by  an  automatic  measuring  system. 
Both  quasi-peak  and  average  measurements  were  performed.  In  the  following  spectral 
diagram, “x” means quasi-peak test results and “+” means average test results. 
Page of 33
Display

Click on the first or last page to see other GO PLAY MICRO (serv.man6) service manuals if exist.