Read Harman Kardon GO PLAY MICRO (serv.man4) EMC - CB Certificate online
Page 68 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
3.2.5.1
Replace
"60245 IEC 53" by "H05 RR-F";
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the
following:
Up to and including 6
"60245 IEC 53" by "H05 RR-F";
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the
following:
Up to and including 6
0,75
1)
Over 6 up to and including 10 (0,75)
2)
1,0
Over 10 up to and including 16 (1,0)
3)
1,5
In the Conditions applicable to Table 3B delete
the words "in some countries" in condition
the words "in some countries" in condition
1)
.
In Note 1, applicable to Table 3B, delete the
second sentence.
second sentence.
N/A
3.3.4
In table 3D, delete the fourth line: conductor
sizes for 10 to 13A, and replace with the
following:
"Over 10 up to
and including 16 1,5 to 2,5 1,5 to 4
Delete the fifth line: conductor sizes for 13 to
16 A.
sizes for 10 to 13A, and replace with the
following:
"Over 10 up to
and including 16 1,5 to 2,5 1,5 to 4
Delete the fifth line: conductor sizes for 13 to
16 A.
N/A
4.3.13.6
Add the following note:
NOTE Attention is drawn to 1999/519/EC: Council
Recommendation on the limitation of exposure of the general
public to electromagnetic fields 0 Hz to 300 GHz. Standards
taking into account this recommendation are currently under
development.
Recommendation on the limitation of exposure of the general
public to electromagnetic fields 0 Hz to 300 GHz. Standards
taking into account this recommendation are currently under
development.
N/A
Annex H
Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
operator access area, the dose rate shall not
exceed 1
At any point 10 cm from the surface of the
operator access area, the dose rate shall not
exceed 1
µSv/h (0,1 mR/h) (see note). Account is
taken of the background level.
Replace the notes as follows:
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete Note 2.
N/A
Annex P
Replace the text of this annex by:
See annex ZA.
See annex ZA.
P
Annex Q
Replace the title of IEC 61032 by "Protection of persons and equipment by
enclosures – Probes for verification".
Add the following notes for the standards indicated:
IEC 60127
enclosures – Probes for verification".
Add the following notes for the standards indicated:
IEC 60127
NOTE Harmonized as EN 60127 (Series) (not modified)
IEC 60269-2-1 NOTE Harmonized as HD 630.2.1 S4:2000 (modified)
IEC 60529
IEC 60529
NOTE Harmonized as EN 60529:1991 (not modified)
IEC 61032
NOTE Harmonized as EN 61032:1998 (not modified)
IEC 61140
NOTE Harmonized as EN 61140:2001 (not modified)
ITU-T Recommendation K.31
NOTE in Europe, the suggested document is EN 50083-1.