1.2.12.101
Addition:
VTM CLASS MATERIAL: Thin MATERIALS fulfil the
specified conditions during the test of clause A.101
applied for materials that the test and evaluation of
clauses A.6 to A.10 is difficult to enforce. Materials are
classified to three classifications as VTM-0, VTM-1 and
VTM-2 according to the conditions after the removal of
the test flame.
VTM CLASS MATERIAL: Thin MATERIALS fulfil the
specified conditions during the test of clause A.101
applied for materials that the test and evaluation of
clauses A.6 to A.10 is difficult to enforce. Materials are
classified to three classifications as VTM-0, VTM-1 and
VTM-2 according to the conditions after the removal of
the test flame.
The material is not used
N/A
1.7.101
Addition:
Marking for CLASS 0I EQUIPMENT
Marking for CLASS 0I EQUIPMENT
For CLASS 0I EQUIPMENT, the following instruction
shall be indicated on the visible place of the mains plug
or the main body:
shall be indicated on the visible place of the mains plug
or the main body:
“Provide an earthing connection”
Moreover, for CLASS 0I EQUIPMENT, the following
instruction shall be indicated on the visible place of the
main body or written in the operating instructions:
instruction shall be indicated on the visible place of the
main body or written in the operating instructions:
“Provide an earthing connection before the mains plug
is connected to the mains. And, when disconnecting
the earthing connection, be sure to disconnect after
pulling out the mains plug from the mains.”
is connected to the mains. And, when disconnecting
the earthing connection, be sure to disconnect after
pulling out the mains plug from the mains.”
Class III equipment
supplied by a separately
certified adaptor. (refer
to summary of testing)
supplied by a separately
certified adaptor. (refer
to summary of testing)
N/A
2.1.1.1
Replacement:
Replace “IEC 60083” to “IEC 60083 or JIS C 8303” in
2.1.1.1 b).
Replace “IEC 60083” to “IEC 60083 or JIS C 8303” in
2.1.1.1 b).
Considered
P
2.6.3.1
Addition:
Add the following after 1st paragraph.
Add the following after 1st paragraph.
This also applies to the conductor of lead wire for
protective earthing of CLASS 0I EQUIPMENT.
protective earthing of CLASS 0I EQUIPMENT.
Class III equipment
supplied by a separately
certified adaptor. (refer
to summary of testing)
supplied by a separately
certified adaptor. (refer
to summary of testing)
N/A
2.6.4.1
Replacement:
Replace 2nd sentence in 1st paragraph.
Replace 2nd sentence in 1st paragraph.
For CLASS I EQUIPMENT with a DETACHABLE
POWER SUPPLY CORD, the earthing terminal in the
appliance inlet is regarded as the main protective
earthing terminal.
POWER SUPPLY CORD, the earthing terminal in the
appliance inlet is regarded as the main protective
earthing terminal.
Class III equipment.
N/A
2.6.5.4
Replacement:
Replace 1st sentence.
Replace 1st sentence.
Protective earthing connections of CLASS I
EQUIPMENT shall make earlier and break later than
the supply connections in each of the following:
EQUIPMENT shall make earlier and break later than
the supply connections in each of the following:
Class III equipment.
N/A