Read Harman Kardon ESQUIRE (serv.man3) EMC - CB Certificate online
Report No.:
EM201300418-1
Application No.:
ZJ00031163
Page 42 of 58
4.5 HOPPING CHANNEL SEQUENCE
4.5.1 LIMITS
EN 300 328 clause 4.3.4.3.2
4.5.2 TEST PROCEDURE
Remove the antenna from the EUT and then connect a low attenuation cable from the antenna port
to the spectrum.
Set the spectrum analyzer: RBW = 100 kHz. VBW ≥ 100 kHz. Sweep = auto; Detector Function =
Peak. Trace = Max hold.
Allow the trace to stabilize. It may prove necessary to break the span up to sections. in order to
clearly show all of the hopping frequencies. The limit is specified in one of the subparagraphs of
this Section.
Set the spectrum analyzer: start frequency = 2400MHz. stop frequency = 2483.5MHz. Submit the
test result graph.
4.5.3 TEST SETUP
EN 300 328 clause 4.3.4.3.2
4.5.2 TEST PROCEDURE
Remove the antenna from the EUT and then connect a low attenuation cable from the antenna port
to the spectrum.
Set the spectrum analyzer: RBW = 100 kHz. VBW ≥ 100 kHz. Sweep = auto; Detector Function =
Peak. Trace = Max hold.
Allow the trace to stabilize. It may prove necessary to break the span up to sections. in order to
clearly show all of the hopping frequencies. The limit is specified in one of the subparagraphs of
this Section.
Set the spectrum analyzer: start frequency = 2400MHz. stop frequency = 2483.5MHz. Submit the
test result graph.
4.5.3 TEST SETUP
4.5.4 TEST RESULTS
Antenna
EUT
Attenuator
Receiver
Click on the first or last page to see other ESQUIRE (serv.man3) service manuals if exist.