DVD 39 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon DVD 39 (serv.man3) EMC - CB Certificate online

Reference No. : 54120801I                                                                                                                        Page 11
 
◀  Anam EMC Test Laboratory  ▶
 
 
8. FLICKER 
   8.1. Operating environment 
Temperature 
: 18℃ 
Relative humidity  : 50% 
 
      8.2. Test set-up and procedure 
 
The open circuit test voltage was the rated voltage of the EUT. 
 
The reference impedance was a conventional impedance being used to calculate 
or measure the disturbance caused by an appliance. 
 
The measurement was performed with the Test software for Windows 
 
8.3. Test instrumentation 
Equipment 
Mfr. 
Type No. 
Serial No. 
Test DVD 
 
TDV-540 
N/A 
Reference impedance 
Voltech 
IEC Standard 555 
IB16/0725 
Universal power analyzer  Voltech 
PM6000 
100006700178 
Programmable controller 
Pacific 
360AMXT/UPC32 
151 
Magnetics module 
Pacific 
134310 
334 
 
8.4. Test result 
 
The equipment does comply with the requirements. 
 
For the measurement data, see Annex D (1 Copies). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 73