Read Harman Kardon DVD 31 (serv.man12) EMC - CB Certificate online
Test report no. JSH0311243-001
Page 12 of 19
8. Radiated emission
8.1 Test result
Pass Fail Not applicable
8.2 Operating environment
Temperature: °C
Relative Humidity: %
8.3 Test set-up and test procedure
The measurement was applied in an semi-anchonic chamber.
The EUT and simulators were placed on a 0.8m high wooden turntable above the horizontal metal
ground plane. The turn table rotated 360 degrees to determine the position of the maximum emission
level. The EUT was set 3 meters away from the receiving antenna which was mounted on an antenna
mask. The antenna moved up and down between from 1meter to 4 meters to find out the maximum
emission level.
Broadband antenna was used as receiving antenna. Both horizontal and vertical polarization of the
antenna were set on measurement. In order to find the maximum emission, all of the interface cables
were manipulated according to EN55022 requirement during radiated test.
The bandwidth setting on R&S Test Receiver ESVS10 was 120kHz.
The frequency range from 30MHz to 1000MHz was checked.
The mode (playing) was checked on radiated disturbance test and all the test results are listed in the
sec.7.6.
Antenna
mask
mask
Turn Table
Pre-amplifier
Test receiver
EUT
Click on the first or last page to see other DVD 31 (serv.man12) service manuals if exist.