Read Harman Kardon DVD 27 (serv.man12) EMC - CB Certificate online
- IEC 60065 6
th
edition (1998)
- Page 36 of 36 -
Order No.
48750
FAULT CONDITION TESTS (Continued)
P
Comp.
No
No
Fault Test
V
Point Test
time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
IC91
S-c
254,4
Pin (1-4)
10 min
F901
0,02 A
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
PC91 S-c
254,4 Pin
(3-4)
10
min
F901 0,02 A
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other DVD 27 (serv.man12) service manuals if exist.