DMC 250 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 49

Read Harman Kardon DMC 250 EMC - CB Certificate online

 
 
- Page 3 of 8 - 
 
   
 Report 
No. 
85787 
 
 
 
 
11 
FAULT CONDITON TESTS -continued 
Comp. 
No. 
Location 
Fault  
Test V  Test 
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
C951 - 
S-c 253 10 
min 
F901 
0,03 A 
Signal output off immediately. 
Input current stabilised at 0,03A. 
No component damaged. 
No hazard. 
D942 
A - C 
S-c 
253 1 
hr 
30 min 
F901
0,19 A 
Normal operated. 
Input current stabilised at 0,19A. 
No component damaged. 
No hazard.
 
D933 
A - C 
S-c 
253 
45 min 
F901
0,03 A 
Unit shut down immediately. 
Input current changed, 
between 0,03A to 0,01A. 
No component damaged. 
No hazard. 
C937 - 
S-c 253 
40 min 
F901
0,03 A 
Unit shut down immediately. 
Input current changed, 
between 0,03A to 0,02A. 
TF91 coil heated up to 23,4K and
 stabilised. 
No component damaged. 
No hazard. 
D932 
A - C 
S-c 
253 
20 min 
F901
0,03 A 
Unit shut down immediately. 
Input current changed, 
between 0,02A to 0,01A. 
No component damaged. 
No hazard. 
C936 - 
S-c 253 
1 hr 
F901
0,04 A 
Unit shut down immediately. 
Input current changed,  
between 0,04A to 0,02A. 
No component damaged. 
No hazard. 
D931 
A - C 
S-c 
253 
10 min 
F901
0,03 A 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard. 
C931 - 
S-c 253 
20 min 
F901
0,04 A 
Unit shut down immediately. 
Input current changed,  
between 0,04A to 0,02A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
 