Read Harman Kardon DIGITAL LOUNGE (serv.man15) Service Manual online
Design Requirements
AV5-Electronic
CONRAC Number
4042-6350-9601
Rev. 1.12
Status: 04.05.2006
Page 38/39
Copyright © CONRAC GmbH. All rights reserved. For internal use only
Nur für internen Gebrauch. Alle Rechte vorbehalten
Pflichtenheft AV5, REV 1.12
4042-6350-9601
5. Qualification
5.1. Ambient
conditions
Operating-temperature :
lower = 5°C (+32°F)
warranted performance
-20°C (-4°F)
no major problem or permanent fault
upper
=
+35°C
(+95°F)
warranted
performance
storage-temperature :
-20°C … +70°C (-4°F … +158°F)
relative humidity
:
< 80%
maximum air pressure:
= 708 hPa (corresponding height 2000m)
5.2. EMI-standards
Criteria
EMI/EMC: EN55013
EN55022-B
D
ESD:
EN61000-4-2 contact discharge 4kV
EN61000-4-2 air discharge 8kV
EN61000-4-2 air discharge 8kV
B
Radiated RF (80-1000MHz):
EN61000-4-3 (20V/m 80% modulation level from 80 –
1000MHz)
1000MHz)
A
Conducted disturbances
induced by RF fields:
induced by RF fields:
EN61000-4-6 (10Veff, AM 80%, 1kHz from 150kHz –
80MHz)
80MHz)
A
Radiated RF:
ENV50204:1995
900MHz, 20V/m, pulse 50%
900MHz, 20V/m, pulse 50%
A
5.3. El.
safety
• EN60065/09.93 + A11 (latest revision)
• EN60950:2000
• Designed to meet UL1950 3
rd
edition or higher
5.4. Vibration and shock
MECHANICAL STRESS
Shock:
20G, 11ms, half sine (x/y direction)
15G, 11ms, half sine (z direction)
Vibration: 1.2G, 10 – 55Hz, sinus
Sweep: 1
Sweep: 1
minute/octave
Amplitude: 0.35mmp-p (x-direction)
0.35mmp-p (y direction)
0.175mmp-p
(z-direction)
Time :
30 minutes
Standard: Conform to EN60605
DL HT32 - HT40 - HT46
Harman Consumer Group International
Click on the first or last page to see other DIGITAL LOUNGE (serv.man15) service manuals if exist.