EM201200178-7 Application No.: ZJ00015407 Page 18 of 45
4.3 DISTURBANCE POWER MEASUREMENT
4.3.1 LIMITS
dBpW
FREQUENCY (MHz)
Quasi-peak
Average
30 ~ 300
45 to 55 (a)
35 to 45 (a)
Note: (a) Increasing linearly with the frequency.
4.3.2 TEST PROCEDURES
The appliance to be tested is placed on a non-metallic table at least 0,4 m from other metallic
objects and the lead to be measured on is stretched in a straight line for a distance sufficient to
accommodate the absorbing clamp, and to permit the necessary measuring adjustment of
position for tuning. The clamp is placed around the lead so as to measure a quantity
proportional to the disturbance power on the lead.
The absorbing clamp is positioned for maximum indication at each test frequency: the clamp
shall be moved along the lead until the maximum value is found between a position adjacent
to the appliance and a distance of about a half-wavelength from it.
The straight portion of the lead to be measured on should therefore be about 6 m long, this
being equal to λ max/2 + 0,6 m in order to allow at any time the positioning of the absorbing
clamp and a possible second clamp for additional isolation. Pre-testing is carried out in all
operating modes to find the worst mode for the every test terminal.
4.3.3 TEST SETUP