Read Harman Kardon BDS 575 EMC - CB Certificate online
Page 6 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
3
General requirements
Safety class of the apparatus .................................. : Class II
P
4
General test conditions
4.1.4
Ventilation instructions require the use of the test
box
box
Test box used
P
5
Marking and instructions
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
spirit
P
5.1
a) Identification, maker ............................................. : harman/kardon
P
b) Model number or type reference .......................... : BDS 575, BDS 275, BDS 577,
BDS 277
P
c) Class II symbol if applicable ................................ : Symbol according to IEC
60417-5172 used
P
d) Nature of supply .................................................... :
P
e) Rated supply voltage ........................................... : 100-240VAC
P
f) Mains frequency if safety dependant ................... : 50/60Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ............................................................................ :
apparatus supplied by supply apparatus for general
use ............................................................................ :
N/A
Measured current or power consumption ............... :
N/A
Deviation % (max 10%) ........................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply . :
us intended for connection to an a.c. mains supply . :
120W for BDS 575, BDS 577;
90W for BDS 275, BDS 277
90W for BDS 275, BDS 277
P
Measured current or power consumption ............... : 77.9W for BDS 575, BDS 577;
64.7W for BDS 275, BDS 277
P
Measured current or power consumption for
Television set ........................................................... :
Television set ........................................................... :
N/A
Deviation % (max 10%) ........................................... : -28.1% Max.
P
5.2
a) Earth terminal
N/A
b) Hazardous live terminals
N/A
c) Markings on supply output terminals
N/A
5.3
a) Use of triangle with exclamation mark
Provided in circuit diagram
P
b) marking on loudspeaker grille, IEC 60417-5036
N/A
5.4
Instructions for use
Provided
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
P