Read Harman Kardon BDS 575 (serv.man2) EMC - CB Certificate online
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E12377 page 15 of 323
3.5. EUT Configuration on Test
The following equipments are installed on conducted emission test to meet EN55013 and
EN55022 requirement and operating in a manner which tends to maximize its emission
characteristics in a normal application.
3.5.1.BLU-RAY DISC SYSTEM
EN55022 requirement and operating in a manner which tends to maximize its emission
characteristics in a normal application.
3.5.1.BLU-RAY DISC SYSTEM
Model Number
: BDS575
Serial Number
: N/A
3.5.2.Support Equipment : As Tested Supporting System Detail, in Section 2.2.
3.6. Operating Condition of EUT
3.6.1.Setup the EUT and simulators as shown in Section 3.2.
3.6.2.Turn on the power of all equipments.
3.6.3. Let the EUT worked in test mode (BD Play/USB Play/BD Live/FM Mode/Coaxial In/
3.6.2.Turn on the power of all equipments.
3.6.3. Let the EUT worked in test mode (BD Play/USB Play/BD Live/FM Mode/Coaxial In/
AUX In / Component Video IN/ Optical In / HDMI In) and test it.
3.7. Test Procedure
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT
Power connected to the power mains through a line impedance stabilization network
(L.I.S.N. #1).The other peripheral devices power cord connected to the power mains
through a line impedance stabilization network (L.I.S.N.#3). This provided a 50ohm
coupling impedance for the tested equipments. Both sides of AC line are checked to find
out the maximum conducted emission levels according to the EN55013 and EN55022
regulations during conducted emission test.
The bandwidth of the test receiver (R&S Test Receiver ESHS10) is set at 10kHz.
The frequency range from 150kHz to 30MHz is checked. The test result are reported on
Section 3.8.
Power connected to the power mains through a line impedance stabilization network
(L.I.S.N. #1).The other peripheral devices power cord connected to the power mains
through a line impedance stabilization network (L.I.S.N.#3). This provided a 50ohm
coupling impedance for the tested equipments. Both sides of AC line are checked to find
out the maximum conducted emission levels according to the EN55013 and EN55022
regulations during conducted emission test.
The bandwidth of the test receiver (R&S Test Receiver ESHS10) is set at 10kHz.
The frequency range from 150kHz to 30MHz is checked. The test result are reported on
Section 3.8.