IEC 60065, 6th edition : 1998
 - 
- Page 44 of 44 - 
 
 
   
 
Order No. 
200211174
 
 
 
 
 
FAULT CONDITION TESTS (continued)   
Comp. 
No 
Fault 
Test V 
Position 
Test time  Fuse No 
Current 
through 
fuse 
Mains power/temperatures/results 
QR911 
S-c 
254,4 
C - E 
1 sec 
F452 
Protection circuit operated 
immediately (
RLY452, RLY453
 off). 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard.   
QR911 
S-c 
254,4 
B - E 
30 min 
F452 
2,46 A 
Normal operating. 
Input current stabilised at 2,46 A. 
No component damaged. 
No hazard.   
Speaker 
Terminal 
 
S-c 
254,4 
Front 
(R-ch.) 
1 sec 
F452 
Protection circuit operated 
immediately (
RLY452, RLY453
 off). 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard.   
Pmax 
operat. 
Maximu
m non -
clipped 
output 
signal 
254,4 
1 hr 
12 min 
F452 
5,21 A 
Main transformer primary winding 
heated up to 122K and thermal cut-
out operated after1 hr 12 min. 
Components are heated up to: 
- Main transf. chassis    
: 103K 
- Sub trans f. pr. winding    : 87K 
- Sub trans f. core   
: 64K 
- St
-by transf
. pr. winding   : 44K 
- St-by transf. core
 
 
: 53K 
- Line filter coil   
: 135K 
- D452 heat-sink   
: 103K 
- PWB near D452 
: 65K 
- Top cover on transf.   
: 49K.
 
Dielectric strength test OK.   
No hazard. 
Top cover 
opening 
Blocked 
254,4 
31 min 
F452 
2,46 A 
Protection circuit operated after   
31 min. (
RLY452, RLY453
 off). 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 