Read Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 21 of 44 -
Order No.
200211174
14.3
Inductors and windings
P
14.3.1
Transformers and inductors marked
with manufacturer's name and type
with manufacturer's name and type
Type:
“55286170NR” for Main transformer,
“5528634ANR” for Sub transformer,
”55286320NR” for Standby transformer.
Manufacturer’s name identification:
“POWER TECHNICS CO.” for Main transformer,
”KS” for Sub and standby transformers.
“55286170NR” for Main transformer,
“5528634ANR” for Sub transformer,
”55286320NR” for Standby transformer.
Manufacturer’s name identification:
“POWER TECHNICS CO.” for Main transformer,
”KS” for Sub and standby transformers.
P
14.3.2.
Transformer category
Isolating transformer
P
14.3.3-5
Transformer construction
See below.
P
14.3.3.2
Transformers meet the
constructional requirements :
constructional requirements :
See below.
P
Transformer/motor
Insulation
Insulation
Test
Flashover
Creepage distances
Part No/markings
between
resistance
voltage
Breakdown
and clearances
M Ohm
kV(60)s
voltage kV
Measured
Required
55286170NR
Pr - sec
> 100
3KV(rms)
-
> 8,0 mm
> 6 mm
5528634ANR
Pr - ic - sec
> 100
3KV (rms)
-
> 6,0 mm
> 6 mm
55286320NR
Pr - ic - sec
> 100
3KV (rms)
-
> 7,4 mm
> 6 mm
Components / construction
(Main transformer)
Concentric winding on an isolate iron core. At least 3
layers of insulation between primary and secondary
winding.
layers of insulation between primary and secondary
winding.
P
Components / construction
(Sub/Standby transformer)
Windings on two separate bobbins. The bobbins are
placed in an insulating housing with two compartments,
one above the other. Bobbin thickness : > 0,4mm.
placed in an insulating housing with two compartments,
one above the other. Bobbin thickness : > 0,4mm.
P
Transformer/mot
or
or
Insulation
Thickness (mm)
Material
Dielectric strength test
Part
No/markings
No/markings
between
X
for each combination of
Number
two (2) layers
55286170NR
Pr - sec
0,05 mm x 3
Polyester film
Pass *)
Pr - sec
0,5 mm x 1
P.T.F.E. Tube
Pass *)
5528634ANR
Pr - sec
0,80 mm min. x 1
PETP bobbin
Pass *)
Pr - ic
0,80 mm min. x 1
PETP bobbin
Pass *)
55286320NR
Pr - sec
0,80 mm min. x 1
PETP bobbin
Pass *)
Pr - ic
0,80 mm min. x 1
PETP bobbin
Pass *)
*) Test voltage: 3000 Vrms.
Click on the first or last page to see other AVR 8500 (serv.man2) service manuals if exist.