AVR 8500 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 25

Read Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate online

 
IEC 60065, 6th edition : 1998
 - 
- Page 21 of 44 - 
 
 
   
 
Order No. 
200211174
 
 
 
 
14.3 
Inductors and windings 
 
 
14.3.1 
Transformers and inductors marked 
with manufacturer's name and type    
Type:   
“55286170NR” for Main transformer, 
“5528634ANR” for Sub transformer, 
”55286320NR” for Standby transformer. 
 
Manufacturer’s name identification:   
“POWER TECHNICS CO.” for Main transformer, 
”KS” for Sub and standby transformers. 
14.3.2. 
Transformer category 
Isolating transformer 
 
14.3.3-5 
Transformer construction 
See below. 
14.3.3.2 
Transformers meet the 
constructional requirements : 
See below. 
Transformer/motor 
Insulation 
Insulation 
Test 
Flashover 
Creepage distances 
Part No/markings 
between 
resistance 
voltage 
Breakdown 
and clearances 
 
 
  M Ohm 
kV(60)s 
voltage kV 
Measured 
Required   
55286170NR 
Pr - sec 
> 100 
3KV(rms) 
> 8,0 mm 
> 6 mm 
5528634ANR 
Pr - ic - sec 
> 100 
3KV (rms) 
> 6,0 mm 
> 6 mm 
55286320NR 
Pr - ic - sec 
> 100 
3KV (rms) 
> 7,4 mm 
> 6 mm 
 
Components / construction 
(Main transformer)
   
Concentric winding on an isolate iron core. At least 3 
layers of insulation between primary and secondary 
winding. 
 
Components / construction 
(Sub/Standby transformer)
   
Windings on two separate bobbins. The bobbins are 
placed in an insulating housing with two compartments, 
one above the other. Bobbin thickness : > 0,4mm. 
Transformer/mot
or 
Insulation 
Thickness (mm) 
Material 
Dielectric strength test 
Part 
No/markings 
between 
            X 
 
for each combination of 
 
 
    Number 
 
two (2) layers   
55286170NR 
Pr - sec 
0,05 mm x 3 
Polyester film 
Pass  *) 
 
Pr - sec 
0,5 mm x 1 
P.T.F.E. Tube 
Pass  *) 
 
 
 
 
 
5528634ANR 
Pr - sec 
0,80 mm min. x 1 
PETP bobbin 
Pass  *) 
 
Pr - ic 
0,80 mm min. x 1 
PETP bobbin 
Pass  *) 
 
 
 
 
 
55286320NR 
Pr - sec 
0,80 mm min. x 1 
PETP bobbin 
Pass  *) 
 
Pr - ic 
0,80 mm min. x 1 
PETP bobbin 
Pass  *) 
*) Test voltage: 3000 Vrms.  
Page of 55
Display

Click on the first or last page to see other AVR 8500 (serv.man2) service manuals if exist.