Read Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 15 of 44 -
Order No.
200211174
9
ELECTRIC SHOCK HAZARD
UNDER NORMAL OPERATING
CONDITIONS
UNDER NORMAL OPERATING
CONDITIONS
P
9.1.1
Touch current expressed as voltages
U1 and U2 in Annex D
U1 and U2 in Annex D
P
Location
Measured U1
V (peak)
V (peak)
Measured U1
V (DC)
V (DC)
Measured U2
V (peak)
V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.0V (DC)
U2 Max 0.35V
(peak)
U1 Max 35V (peak)
U1 Max 1.0V (DC)
U2 Max 0.35V
(peak)
Mains pole - RCA terminal
< 1,56 V
-
< 0,10 V
Pass
Discharge not exceeding 45
µ
C
No part or contact of a terminal with stored voltages
between 60V - 15kV
between 60V - 15kV
N
Energy of discharge not exceeding
350 mJ
350 mJ
No part or contact of a terminal with stored voltages
exceeding 15kV
exceeding 15kV
N
Test with test finger according to
test probe B of IEC 61 032 (20N)
test probe B of IEC 61 032 (20N)
No access to hazardous live parts
P
For class II constructions, test with
test probe 13 of IEC 61 032 (3N)
test probe 13 of IEC 61 032 (3N)
No access to hazardous live parts
P
Clearances to circuits exceeding
1000V a.c. or 1500V d.c.
1000V a.c. or 1500V d.c.
No voltages exceeding 1000V AC or 1500V DC.
N
9.1.2
No hazardous live shafts of knobs,
handles or levers
handles or levers
No live shafts, handles or levers
N
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with
1 mm x 20 mm test pin (10 N); test
probe 16 of IEC 61 032
1 mm x 20 mm test pin (10 N); test
probe 16 of IEC 61 032
Does not reach hazardous live parts
P
Terminal devices tested with
1 mm x 100 mm straight wire (1 N);
test probe D of IEC 61 032
1 mm x 100 mm straight wire (1 N);
test probe D of IEC 61 032
Does not reach hazardous live parts
P
9.1.5
Pre-set controls tested with
2.5 mm x 100 mm test pin (10 N);
test probe C of IEC 61 032
2.5 mm x 100 mm test pin (10 N);
test probe C of IEC 61 032
No preset controls
N
9.1.6
No shock hazard due to stored
charge on withdrawal of the mains
plug; voltage (V) after 2 s
charge on withdrawal of the mains
plug; voltage (V) after 2 s
Measured voltage after 2 sec.: < 2V.
P
If C is not greater than 0,1
µ
F no test
needed
N
9.1.7
Enclosure sufficiently resistant to
external force
external force
P