115882
5 MARKING
Comprehensible and easily discernible
On front and rear side of
the enclosure.
the enclosure.
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / sprit.
P
5.1 Identification,
maker, model ............................... :
Brand: Harman Kardon
Model: AVR760, or AVR660
See copy of marking plate.
Model: AVR760, or AVR660
See copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied in
according to IEC 60417-5172
according to IEC 60417-5172
P
Rated
supply
voltage and symbol ..................... :
“230-240V” and AC-symbol
( ~ ) used.
( ~ ) used.
P
Frequency if safety dependant
50Hz
P
Rated current or power consumption ............... :
1220W
P
14 COMPONENTS
14.5 Protective
devices
P
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are approved
components according to
IEC 60127.
See appended table, list of
critical components.
components according to
IEC 60127.
See appended table, list of
critical components.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder
:
:
The following marking applied
close to fuses;
Mains fuses;
F3001: T6.3A L 250V
F3101: T2A L 250V
Secondary fuses;
F101 - F104: T2A L 250V
F801, F802: T4A L 250V
F220, F221: T3.15A L 250V
close to fuses;
Mains fuses;
F3001: T6.3A L 250V
F3101: T2A L 250V
Secondary fuses;
F101 - F104: T2A L 250V
F801, F802: T4A L 250V
F220, F221: T3.15A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel :
No possible to connect
fuses in parallel.
fuses in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool
:
replacing fuse-links without the use of a tool
:
No replacement of fuse
possible by hand.
possible by hand.
P