Read Harman Kardon AVR 660 (serv.man2) EMC - CB Certificate online
Harman Kardon Inc. Page 24 of 103
AVR760 (Harman Kardon)
EMC Test Report
Reference No.: NK08E 683.EMI
10. Fluctuating Harmonics (EN 61000-3-2)
10.1 Test Procedure
EUT was connected to the Power Analyzer system. Measurements were conducted on all active phases,
for harmonics 1-40th of the mains frequency (50 or 60 Hz). A pure AC mains was supplied to the
system from two power supply units. The units supply an AC mains, free of harmonics or distortion of
any kind. An overview of the harmonic emission is presented as numeric and as graphics.
Instrumentation used during this session:
Instruments
Manufacturer
Model
Serial number
Due to Calibration
PM6000 Universal
Power Analyzer
Voltech PM6000
100006700119
2009.04
Reference Impedance
Network
Voltech IEC61000-3
IG14210971
2009.04
AC Power Source
Pacific Power
Source Inc.
360AMXT-
UPC32/M5283
0926-03765 2009.04
10.2 Test Parameters
Port:
AC Mains
Test Engineer:
J. H. Ko
Basic Standard:
EN 61000-3-2:2006
Class:
A
10.3 Fluctuating Harmonics, Graphic Presentation
Measurement results can be found in the
Appendix C
.
Result
Compliant
10.4 Remarks
Speaker Output Conditions
Power
Consumption
Speaker Channel
L
32.15
V
11.25
V
8 ohm
Front
R
32.10
V
11.20
V
8 ohm
Speaker Channel
L
31.50
V
11.12
V
8 ohm
Rear
R
31.50
V
11.16
V
8 ohm
Speaker Center
32.40
V
11.45
V
8 ohm
Speaker Channel
L
31.50
V
11.11
V
8 ohm
Rear Back
R
31.80
V
11.31
V
8 ohm
Speaker
Pmax.
Channel
1,420 W
1/8 Pmax.
600 W
Impedance