AVR 460 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 57

Read Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate online

 
 
- Page 2 of 10- 
 
 
 
 
 Report 
No. 
129952 
  
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065_I 
6.1 
Replace the entire subclause by: 
Apparatus including a potential source of ionizing 
radiation shall be so constructed that personal 
protection against ionizing radiation is provided 
under normal operating conditions and under fault 
conditions. 
Compliance is checked by measurement under the 
following conditions: 
In addition to the normal operating conditions, all 
controls adjustable from the outside BY HAND, by 
any object such as a tool or a coin, and those 
internal adjustments or pre-sets which are not 
locked in a reliable manner, are adjusted so as to 
give maximum radiation whilst maintaining an 
intelligible picture for 1 h, at the end of which the 
measurement is made. 
NOTE Soldered joints and paint lockings are 
examples of adequate locking. 
The amount of ionizing radiation is regulated by 
European Council Directive 96/29/Euratom of 13 
May 1996. This directive requires that at any point 
10 cm from the outer surface of the apparatus, the 
dose-rate shall not exceed 1µSv/h (0.1 Mr/h) taking 
account of the background level. 
Moreover, the measurement shall be made under 
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is maintained 
for 1 h, at the end of which the measurement is 
made. 
A picture is considered to be intelligible if the 
following conditions are met: 
- a scanning amplitude of at least 70% of the usable 
screen width; 
- a minimum luminance of 50 cd/m² with locked 
blank raster provided by a test generator; 
- a horizontal resolution corresponding to at least 1.5 
MHz in the centre, with a similar vertical 
degradation; 
not more than over flashover per 5 min. 
No ionizing radiation in the  
equipment 
N/A 
13.3.1 
Delete note 4. 
Deleted 
N/A 
14  
Delete note 4 and note 5. 
Deleted 
N/A 
15.1.1 
Delete notes 1 and 2. 
Deleted 
N/A 
15.2 
Delete note 2. 
Deleted 
N/A 
16.1 
Delete note 1. 
Deleted 
N/A 
16.2 
Delete the note. 
Deleted 
N/A 
20 
Delete note 2. 
Deleted 
N/A 
Page of 65
Display