Read Harman Kardon AVR 435 (serv.man5) EMC - CB Certificate online
EMC Test Report
Reference No.: NK2FE 131.EMI
WOORI Technology Inc. Page 17 of 85
AVR435/230 (Harman Kardon)
8. Radiated Disturbance
8.1 Test Procedure
The measurements were performed in the frequency range 30-1000 MHz
The disturbance radiation was measured on an open area test site with a reference ground plane and at a
distance of 3 m. The height of the measuring antenna was varied between 1 to 4 m and the table was rotated
a full revolution order to obtain maximum values of the electric field intensity.
The measurement was made in both the vertical and horizontal polarization, and the maximum value is
presented in the data. Disturbance radiation due to the local oscillator and its fundamental and harmonic
frequencies was measured on a selected number of broadcast channels.
Instrumentation used during this session:
Instruments
Manufacturer
Model
Serial number
Due To Calibration
Test Receiver
Rohde&Schwarz
ESCS30 833364/020
2005.
09
Amplifier HP
8447F
2805A03351 2005.
04
Logbicon Super Ant.
Schwarzbeck
VULB9166
1067
2005. 04
Position Controller
EM Engineering N/A
N/A
N/A
Turntable EM
Engineering
N/A
N/A
N/A
8.2 Measurement Uncertainty
Radiated disturbance electric field intensity: ±3.0dB
8.3 Test Parameters
Port:
Enclosure
Basic Standard:
EN55013: 2001+A1: 2003
Test Engineer:
J. Y. Yu
IF Bandwidth:
120kHz
Measurement Time:
0.2Sec
Frequency Range:
30MHz – 1GHz