ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
15.1.1
DK: To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following dimensions:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following dimensions:
Dimensions in mm
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.
Justification
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.
Justification
:
Heavy Current Regulations, Section 107
Class II socket-outlet provided.
P
15.1.1
IE: Apparatus which is fitted with a flexible cable or
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification:
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification:
SI 525: 1997
When marketing in Ireland,
the apparatus must be supplied
with a cord and plug acceptable
in Ireland.
the apparatus must be supplied
with a cord and plug acceptable
in Ireland.
N/A