Read Harman Kardon AVR 345 (serv.man2) EMC - CB Certificate online
Reference No. : 54120703A Page 10
◀ Anam EMC Test Laboratory ▶
Disturbance radiation due to the other source.
Disturbance value(㏈㎶/m)
Channel Harmonic Measured
freq. (㎒)
Limit
(㏈㎶/m)
Horizon Vertical
122.887
40.0
38.5
38.6
Others 135.175
40.0
33.6 34.2
147.463
40.0
37.5 34.3
30
~
159.753
40.0
33.5 *
1,000 ㎒
172.038 40.0
38.5 33.2
196.619
40.0
32.1 *
221.197 40.0
36.2 33.7
245.773
47.0
35.3 34.5
258.061
47.0
33.2 *
270.349
47.0
35.1 37.1
282.638
47.0
36.4 35.4
294.926
47.0
37.8 35.3
319.504
47.0
37.9 38.2
331.792
47.0
38.2 42.5
344.080
47.0
36.7 34.5
639.011
47.0
40.1 40.1
*: less than25.0 ㏈㎶/m