Reference No. : 54120503C                                                                                                                        Page 5
 
◀  Anam EMC Test Laboratory  ▶
 
 
 
The test have been performed on the EUT provided with the following 
modifications: None. 
 
3.TEST SPECIFICATIONS 
 
   3.1. Standards 
 *EN55013 
(2001): 
Sound and Television broadcast receivers and Associated equipment 
-Radio Disturbance characteristics - Limits and methods of measurement. 
 *EN61000-3-2 
(2000): 
Part 3-2: Limits- Limits for harmonic current emissions 
 
(Equipment input current  ≤16A per phase) 
 
*EN61000-3-3 (1995 +Amd.1;2001): 
 
 Part 3-3: Limits- Limitation of voltage changes, voltage fluctuations and 
flicker in public low-voltage supply systems for equipment with rated 
current  ≤16A. 
      3.2. Additions, deviations and exclusions from standard 
 
No additions, deviations or exclusions have been made from standard. 
 
      3.3. Purpose of the test: 
 
To determine whether the EUT fulfils the EMC-emission requirements of the   
 
Standards stated in section 3.1. 
 
      3.4. Mode of operation during the test 
 
The EUT was operated in such a way as to deliver one-eighth on the non-clipped 
 
output power to the rated load impedance using the sinusoidal of 1 ㎑. 
 
The EUT was set to the mode of Tuner. 
 
4.TEST SUMMARY 
 
The results in this report apply only to sample(s) tested: 
Test item 
Passed 
the test 
Note 
Mains terminal disturbance voltage 
Yes 
 
Disturbance Radiation 
Yes 
 
Antenna Terminal Disturbance Voltage 
Yes 
 
Disturbance Power 
Yes 
 
Harmonics Yes 
 
Voltage Fluctuations-Flicker 
Yes 
 
 
The equipment does comply with the requirements. 