Read Harman Kardon AVR 335 EMC - CB Certificate online
Reference No. : 54120503C Page 5
◀ Anam EMC Test Laboratory ▶
The test have been performed on the EUT provided with the following
modifications: None.
3.TEST SPECIFICATIONS
3.1. Standards
*EN55013
*EN55013
(2001):
Sound and Television broadcast receivers and Associated equipment
-Radio Disturbance characteristics - Limits and methods of measurement.
-Radio Disturbance characteristics - Limits and methods of measurement.
*EN61000-3-2
(2000):
Part 3-2: Limits- Limits for harmonic current emissions
(Equipment input current ≤16A per phase)
*EN61000-3-3 (1995 +Amd.1;2001):
Part 3-3: Limits- Limitation of voltage changes, voltage fluctuations and
flicker in public low-voltage supply systems for equipment with rated
current ≤16A.
flicker in public low-voltage supply systems for equipment with rated
current ≤16A.
3.2. Additions, deviations and exclusions from standard
No additions, deviations or exclusions have been made from standard.
3.3. Purpose of the test:
To determine whether the EUT fulfils the EMC-emission requirements of the
Standards stated in section 3.1.
3.4. Mode of operation during the test
The EUT was operated in such a way as to deliver one-eighth on the non-clipped
output power to the rated load impedance using the sinusoidal of 1 ㎑.
The EUT was set to the mode of Tuner.
4.TEST SUMMARY
The results in this report apply only to sample(s) tested:
Test item
Passed
the test
Note
Mains terminal disturbance voltage
Yes
Disturbance Radiation
Yes
Antenna Terminal Disturbance Voltage
Yes
Disturbance Power
Yes
Harmonics Yes
Voltage Fluctuations-Flicker
Yes
The equipment does comply with the requirements.