AVR 330 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 40

Read Harman Kardon AVR 330 (serv.man13) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 36 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
C902 S-c 
207  - 
10 
min 
F907 
F903 
F904 
Front, SB/MULTI channels signal 
output off immediately. 
Input current stabilised at 0,85 A. 
F903, F904 opened. 
No hazard. 
C902 S-c 
254,4 - 
10 
min 
F907 
F903 
F904 
Front, SB/MULTI channels signal 
output off immediately. 
Input current stabilised at 0,89 A. 
F903, F904 opened. 
No hazard. 
D992 
S-c 
207 
AC - + 
10 min 
F907 
F905 
F906 
- Normal 
operating. 
Input current stabilised at 1,70A. 
F906 opened. 
No hazard. 
D992 
S-c 
254,4 
AC - + 
10 min 
F907 
F905 
F906 
- Normal 
operating. 
Input current stabilised at 1,78A. 
F906 opened. 
No hazard. 
C915 S-c 
254,4 - 
10 
min 
F907 
F905 
F906 
Center, Surround channels signal 
output off immediately. 
Input current stabilised at 1,21A. 
F905, F906 opened. 
No hazard. 
Q803 
S-c 
207 
C - E 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F905, F906 opened. 
No hazard. 
Q803 
S-c 
254,4 
C - E 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F905, F906 opened. 
Q804 shorted. 
No hazard. 
Q803 
S-c 
254,4 
B - C 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
No component damaged. 
No hazard. 
C807 S-c 
254,4 - 
20 
min 
F907 
F905 
F906 
2,16 A 
Surround L channel signal output 
distorted immediately. 
Input current stabilised at 1,61A. 
R821 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 