Read Harman Kardon AVR 330 (serv.man13) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 10 of 38 -
Order
No.
11152
HEATING
∆
t = ( R2 - R1) x (234,5 + t1) - (t2 - t1)
R1
P
t1 =
27,5 °C
27,5 °C
t2 =
25,5 °C
25,5 °C
Test voltage
207 V
254,4 V
Winding
R1/
Ω
R2/
Ω
∆
t measured
∆
t allowed *
Insulation
class
class
Main transf. pr. winding (207V)
1,821
2,193
55,5
85
Class E
Sub transf. pr. winding (207V)
2892
3233
32,9
85
Class E
Main transf. pr. winding (254,4V)
1,821
2,271
66,7
85
Class E
Sub transf. pr. winding (254,4V)
2892
3383
46,5
85
Class E
Other measured parts
∆
t measured
at 207V
∆
t measured
at 254,4V
∆
t allowed *
Main transformer core
41,2
51,1
85
Sub transformer core
26,3
35,4
85
Diode, D991 body
42,7
48,6
-
Diode, D992 body
35,5
39,7
-
D992
heat-sink
36,2 40,5 -
PWB near D992
34,3
38,9
85
TR, Q803 body
48,7
60,4
-
TR, Q804 body
32,8
42,4
-
TR, Q854 body
46,6
60,1
-
PWB near Q804
43,3
55,4
85
E. Capacitor, C909 body
17,9
22,2
-
E. Capacitor, C929 body
34,8
43,3
-
IC91
heat-sink
47,6 63,6 -
Resistor, R810 body
36,4
44,6
-
Main
heat-sink
34,4 47,0 -
Fan body (on heat-sink)
29,6
37,7
60
Fan body (on back cover)
21,6
26,2
60
Power cord bushing
16,9
21,6
60
Click on the first or last page to see other AVR 330 (serv.man13) service manuals if exist.