AVR 270 (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon AVR 270 (serv.man4) EMC - CB Certificate online

 
Anam Electronics Co., Ltd.                                    Page 12 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
6. Conducted Disturbance at the Mains Port 
 
6.1 Test Procedure 
     
 
        The measurements were performed in a shielded enclosure. EUT was connected to an Artificial   
        Mains Network (AMN). EUT was placed on a wooden table 0.8 m above the grounded floor and at 
        least 0.4 m from the reference ground plane (wall), EUT was placed at least 0.8 m from, and   
        connected via a 1 m mains cable, to the AMN. 
        The measurements on the terminals for mains connection were conducted between neutral and ground,   
        and between phase and ground, in the frequency range 150 kHz to 30 MHz. 
        A peak detector scan was conducted over the defined frequency range on all phases. A comparison   
        of the results obtained from the different phases was then conducted to find the most emitting phase   
        for each frequency. This “Worst Case” scan with quasi-peak detector & average detector was presented   
detector. Instrumentation used during this session:     
Instruments Manufacturer 
Model 
Serial or Firmware   
(No./Ver.) 
Due to   
Calibration  
EMI Test Receiver 
Rohde & Schwarz 
ESCI 
101041 
2013.04 
Software Rohde 
Schwarz 
EMC32 
8.40.0 
TWO-LINE  
V-NETWORK 
Rohde & Schwarz 
ENV216 
101156 
2013.04 
Artificial Mains   
Network 
Rohde & Schwarz 
ESH2-Z5 
100273 
2013.04 
ISN SCHWARZBECK 
ISN 
CAT 
8158-0036 
2013.05 
 
6.2 Measurement Uncertainty 
 
Mismatch + 0.81, u
c
 = 1.43 dB 
U = 2 x 1.43 = 2.86 dB 
U = ku
c
 (CL is 95 %, k = 2)
 
 
Mismatch - 0.89, u
c
 = 1.45 dB 
U = 2 x 1.45 = 2.9 dB 
U = ku
c
 (CL is 95 %, k = 2)
 
 
6.3 Test Parameters 
 
Port: 
a.c. mains   Test 
Engineer: 
Wonho Son 
Test Standard: 
EN 55022:2010 (Class B) 
Frequency Range: 
Frequency Step: IF 
Bandwidth: Measurement 
Time: 
150 kHz – 30 MHz 
5 kHz 
9 kHz 
0.2 s 
 
 
 
Page of 57