Report No.: 163977
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
5.4.1 
Norway and Sweden  
To the end of 5.4.1 (after the compliance statement) the 
following is added:  
The screen of the cable distribution system is normally 
not earthed at the entrance of the building and there is 
normally no equipotential bonding system within the 
building. Therefore the protective earthing of the building 
installation need to be isolated from the screen of a 
cable distribution system.  
It is however accepted to provide the insulation external 
to the equipment by an adapter or an interconnection 
cable with galvanic isolator, which may be provided by 
e.g. a retailer.  
The user manual shall then have the following or similar 
information in Norwegian and Swedish language 
respectively, depending on in what country the 
equipment is intended to be used in:  
“Equipment connected to the protective earthing of the 
building installation through the mains connection or 
through other equipment with a connection to protective 
earthing – and to a cable distribution system using 
coaxial cable, may in some circumstances create a fire 
hazard. Connection to a cable distribution system has 
therefore to be provided through a device providing 
electrical isolation below a certain frequency range 
(galvanic isolator, see EN 60728-11)”  
NOTE In Norway, due to regulation for installations of 
cable distribution systems, and in Sweden, a galvanic 
isolator shall provide electrical insulation below 5 MHz. 
The insulation shall withstand a dielectric strength of 1,5 
kV r.m.s., 50 Hz or 60 Hz, for 1 min.  
Translation to Norwegian (the Swedish text will also be 
accepted in Norway):  
“Utstyr som er koplet til beskyttelsesjord via nettplugg 
og/eller via annet jordtilkoplet utstyr – og er tilkoplet et 
kabel-TV nett, kan forårsake brannfare. For å unngå 
dette skal det ved tilkopling av utstyret til kabel-TV nettet 
installeres en galvanisk isolator mellom utstyret og 
kabel-TV nettet.”  
Translation to Swedish:  
”Utrustning som är kopplad till skyddsjord via jordat 
vägguttag och/eller via annan utrustning och samtidigt är 
kopplad till kabel-TV nät kan i vissa fall medfőra risk főr 
brand.  
Főr att undvika detta skall vid anslutning av utrustningen 
till kabel-TV nät galvanisk isolator finnas mellan 
utrustningen och kabel-TV nätet.” 