Read Harman Kardon AVR 260 (serv.man2) EMC - CB Certificate online
Reference No. : 54120802A Page 7
◀ Anam EMC Test Laboratory ▶
5.4. Test instrument
Equipment
Manufacturer
Type No.
Serial No.
Test site
Shielded room
-
-
Measurement
Receiver
Receiver
R & S
ESCI
100348
R & S
ESH3-Z5
844249/020
Artificial mains
Network EMCO 3825/2 90101718
R. C. Oscillator
Network EMCO 3825/2 90101718
R. C. Oscillator
Kenwood
AG-203A
3090241
Signal Generator
Anritsu
MG3632A
MT79870
* R & S: Rohde & Schwarz
5.5. Test protocol
Date: January 31, 2008
Grounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A.
report as Annex A.
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner .150 66.0 42.3 43.3 56.0 21.7 22.7
12.288 60.0 22.2 21.8 50.0 22.3 21.8
Ungrounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A
report as Annex A
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner .150 66.0 42.0 43.0 56.0 21.5 22.8
12.288 60.0 21.5 20.8 50.0 21.7 20.0
ANAL
OG 1
.150 66.0 51.6 51.5 56.0 26.5 26.8
12.288 60.0 21.3 23.5 50.0 21.5 23.5
The equipment does comply with the requirements.
For the measurement data, see Annex A (6 Copies).