AVR 230 (serv.man12) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 41

Read Harman Kardon AVR 230 (serv.man12) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 36 of 37 - 
 
 
   
 Order 
No. 
14399 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
C922 
S-c 
254,4 
30 min 
F907 
1,73 A 
FL display off immediately. 
Input current stabilised at 1,71A. 
No component damaged. 
No hazard. 
D904 
S-c 
254,4 
A - C 
10 min 
F907 
1,70 A 
Normal operating. 
Input current stabilised at 1,63A. 
R104 opened. 
No hazard. 
C929 
S-c 
254,4 
10 min 
F907 
1,35 A 
Output signal off immediately. 
Input current stabilised at 0,42A. 
R104, R105 opened. 
No hazard. 
C923 
S-c 
254,4 
10 min 
F907 
1,09 A 
Output signal off immediately. 
Input current stabilised at 0,49A. 
No component damaged. 
No hazard. 
D962 
S-c 
254,4 
A - C 
16 min 
1,69 A 
Sub transformer primary winding 
heated-up to 119K and thermal fuse 
opened after 16 min. 
Dielectric strength test O.K. 
No hazard. 
C906 
S-c 
254,4 
13 min 
< 0,04 A
Mains relay off immediately. 
Sub transformer primary winding 
heated-up to 111K and thermal fuse 
opened after 13 min. 
Dielectric strength test O.K. 
No hazard. 
C907 
S-c 
254,4 
1 hr 
< 0,02 A
Mains relay off immediately. 
Sub transformer primary winding 
heated-up to 83K and stabilised. 
Dielectric strength test O.K. 
No hazard. 
D902 
S-c 
254,4 
A - C 
10 min 
1,63 A 
Normal operating. 
Input current stabilised at 1,62A. 
No component damaged. 
No hazard. 
C911 
S-c 
254,4 
13 min 
< 0,04 A
Mains relay off immediately. 
Sub transformer primary winding 
heated-up to 111K and thermal fuse 
opened after 13 min. 
Dielectric strength test O.K. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 