Read Harman Kardon AVR 171 (serv.man5) EMC - CB Certificate online
Page 5 of 6
Report No.: 232174
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Table 8、
Table 9、
Table 10
Table 9、
Table 10
Bellow the headings of Table 8 Table 9 and Table
10 ,added :
“(Applicable for altitude up to 2000m)”
10 ,added :
“(Applicable for altitude up to 2000m)”
Noted
Amended Table 9 Note 2:
For operating voltage values exceeding of table 8,
extrapolation is permitted.
For operating voltage values exceeding of table 8,
extrapolation is permitted.
Noted
13.3.3
After the first paragraph, added a paragraph:
The requirements in table 10 apply to apparatus
intended to be used at altitude not exceeding 2 000
m. For apparatus intended to be operated at
altitudes between 2 000m and 5 000m , Minimum
CLEARANCE limits shall multiply with multiplication
factor 1.48 in table A.2 of GB/T 16935.1. For
apparatus intended to be operated at altitude more
than 5 000m , Minimum CLEARANCES limit shall
multiply with corresponding multiplication factor in
table A.2 of GB/T 16935.1.
The requirements in table 10 apply to apparatus
intended to be used at altitude not exceeding 2 000
m. For apparatus intended to be operated at
altitudes between 2 000m and 5 000m , Minimum
CLEARANCE limits shall multiply with multiplication
factor 1.48 in table A.2 of GB/T 16935.1. For
apparatus intended to be operated at altitude more
than 5 000m , Minimum CLEARANCES limit shall
multiply with corresponding multiplication factor in
table A.2 of GB/T 16935.1.
The apparatus intended to
be operated at altitudes up to
2 000m.
be operated at altitudes up to
2 000m.
N/A
15.1.1
After the first paragraph, added a paragraph:
Plugs connected to the MAINS in apparatus shall
comply with GB 1002 or GB 1003.
Plugs connected to the MAINS in apparatus shall
comply with GB 1002 or GB 1003.
Mains plug and appliance
couplers with cord complying
Chinese National and Industrial
standards provided, and see
couplers with cord complying
Chinese National and Industrial
standards provided, and see
also summary of testing.
P
18
Delete the first paragraph except the first sentence. N/A
18.1
Replaced contents of two dashes in the fourth
paragraph:
— for intrinsically protected tubes, including those
paragraph:
— for intrinsically protected tubes, including those
having integral protective screens, compliance
is checked according to GB27701.
— for tubes non-intrinsically protected checked by
18.2.
18.2.
N/A
18.2
Delete clause 18.2 and renumber the existing
clause 18.3 as 18.2.
clause 18.3 as 18.2.
N/A
Click on the first or last page to see other AVR 171 (serv.man5) service manuals if exist.