ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
5.4.1
Norway and Sweden
To the end of 5.4.1 (after the compliance statement) the
following is added:
The screen of the cable distribution system is normally
not earthed at the entrance of the building and there is
normally no equipotential bonding system within the
building. Therefore the protective earthing of the building
installation need to be isolated from the screen of a
cable distribution system.
It is however accepted to provide the insulation external
to the equipment by an adapter or an interconnection
cable with galvanic isolator, which may be provided by
e.g. a retailer.
The user manual shall then have the following or similar
information in Norwegian and Swedish language
respectively, depending on in what country the
equipment is intended to be used in:
“Equipment connected to the protective earthing of the
building installation through the mains connection or
through other equipment with a connection to protective
earthing – and to a cable distribution system using
coaxial cable, may in some circumstances create a fire
hazard. Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)”
NOTE In Norway, due to regulation for installations of
cable distribution systems, and in Sweden, a galvanic
isolator shall provide electrical insulation below 5 MHz.
The insulation shall withstand a dielectric strength of 1,5
kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also be
accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via nettplugg
og/eller via annet jordtilkoplet utstyr – og er tilkoplet et
kabel-TV nett, kan forårsake brannfare. For å unngå
dette skal det ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret og
kabel-TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och samtidigt är
kopplad till kabel-TV nät kan i vi
To the end of 5.4.1 (after the compliance statement) the
following is added:
The screen of the cable distribution system is normally
not earthed at the entrance of the building and there is
normally no equipotential bonding system within the
building. Therefore the protective earthing of the building
installation need to be isolated from the screen of a
cable distribution system.
It is however accepted to provide the insulation external
to the equipment by an adapter or an interconnection
cable with galvanic isolator, which may be provided by
e.g. a retailer.
The user manual shall then have the following or similar
information in Norwegian and Swedish language
respectively, depending on in what country the
equipment is intended to be used in:
“Equipment connected to the protective earthing of the
building installation through the mains connection or
through other equipment with a connection to protective
earthing – and to a cable distribution system using
coaxial cable, may in some circumstances create a fire
hazard. Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)”
NOTE In Norway, due to regulation for installations of
cable distribution systems, and in Sweden, a galvanic
isolator shall provide electrical insulation below 5 MHz.
The insulation shall withstand a dielectric strength of 1,5
kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also be
accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via nettplugg
og/eller via annet jordtilkoplet utstyr – og er tilkoplet et
kabel-TV nett, kan forårsake brannfare. For å unngå
dette skal det ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret og
kabel-TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och samtidigt är
kopplad till kabel-TV nät kan i vi
ssa fall medfőra risk főr
brand.
Főr att undvika detta skall vid anslutning av utrustningen
till kabel-TV nät galvanisk isolator finnas mellan
utrustningen och kabel-TV nätet.”
Főr att undvika detta skall vid anslutning av utrustningen
till kabel-TV nät galvanisk isolator finnas mellan
utrustningen och kabel-TV nätet.”
Class II apparatus
N/A