AVR 165 (serv.man5) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon AVR 165 (serv.man5) EMC - CB Certificate online

 
 
 
Page 9 of 44 
 
Report No.: 162890 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
General requirements 
 
 
Safety class of the apparatus  ..................................  
Class II apparatus 
 
General test conditions 
 
4.1.4 
Ventilation instructions require the use of the test 
box  
Tested in a open space  
according to manufacturer’s  
instructions 
N/A 
 
Marking and instructions 
 
 
Comprehensible and easily discernible 
On front and rear side of the 
enclosure 
 
Permanent durability against water and petroleum 
spirit  
Tested with water / sprit 
5.1 
a) Identification, maker  ............................................ :  Trade mark: 
 
See copy of marking plate 
 
b) Model number or type reference .......................... :  AVR 165/230 
See copy of marking plate. 
 
c) Class II symbol if applicable  ................................ :  Class II symbol is applied in 
according to IEC 60417-5172 
 
d) Nature of supply.................................................... :  a. c. symbol is applied in 
according to IEC 60417-5032 
 
e) Rated supply voltage  ........................................... :  220-240V and 
AC-symbol ( ~ ) used. 
 
f) Mains frequency if safety dependant  ................... :  50/60Hz 
 
g) Rated current or power consumption for apparatus 
supplied by supply apparatus for general use  ............ : 
The apparatus is connection 
to an a. c. mains supply. 
N/A 
 
Measured current or power consumption  ............... :   
N/A 
 
Deviation %  (max 10%)  .......................................... :   
N/A 
 
h) Power consumption marking for apparatus other 
than single phase  ..................................................... : 
The apparatus is connection 
to an a. c. mains supply. 
N/A 
 
i) Rated current or power consumption for apparatus 
intended for connection to an a.c. mains supply  ......... : 
280W 
 
Measured current or power consumption  ............... :  200W 
(refer to appended table 7.1) 
 
Deviation %  (max 10%)  .......................................... :  Not exceed the marked  value 
Page of 81