AVR 165 (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 110

Read Harman Kardon AVR 165 (serv.man4) EMC - CB Certificate online

 
Anam Electronics Co., Ltd.                                        Page 13 of 17
 
AVR165/230 
EMC Test Report
 
         
Reference No.:NK-11-E-005
 
8. Fast Transients/Burst 
 
8.1 Test Procedure 
 
The minimum area of the ground reference plane is 1 m x 1 m, and connected to earth via a low   
impedance connection.   
The EFT/Burst generator was located on the ground reference plane. 
The EUT was located 0.1 m above the ground reference plane and the length of power line between the   
EFT/Burst generator and the EUT is 0.5 m. 
        The minimum distance between the EUT and all other conductive structures, except the ground   
reference plane is more than 0.5 m. 
The test voltage was applied simultaneously between each of the power supply conductors and the   
protective earth at the power supply. 
Instrumentation used during this session: 
 
Instruments Manufacturer 
Model  Serial number
Due to Calibration 
EFT/Burst Simulator 
Noiseken 
FNS-AXⅡB50
0199B01147 2011.11
 
 
8.2 Test Parameters 
 
Port: 
a.c. mains   
 
 
Basic Standard: 
EN 61000-4-4:2004 
Performance Criteria:  
Performance Results : 
Test Engineer: 
Kyounghoon Lee 
Duration: 
120 s 
Test Data 
Tr/Th    5/50 ns 
Frep  5 kHz 
Trep  300 ms 
 
8.3 Test Log 
 
Line Voltage 
Coupling 
Inject Time 
(sec) 
Result  
(Pass/Fail) 
L1-L2 
± 0.5 kV, ±1 kV 
Direct 120 
Pass 
       
Comment/Performance 
No operation errors were detected during and after the test. 