Read Harman Kardon AVR 161 (serv.man6) EMC - CB Certificate online
Reference No. : 54121302E Page 14/45
◀ Anam EMC Test Laboratory ▶
8.5. Test protocols
Date: January 28, 2013
The equipment does comply with the requirements. Operating condition: The
EUT continuously operated with audio frequency of 1,000 ㎐ color bar being
supplied from the Oscillator or test CD. An absorbing clamp was placed
around all leads. At each mode, the maximum value at each testing frequency
and each output lead was registered and attached as follows.
Test Lead
Freq.
(㎒)
Limit(㏈㎺) Result(㏈㎺)
QP AV QP AV
PHONES
41.70
45.4 35.4 23.3 19.1
ANALOG 1
273.00
54.4
44.4
*
*
ANALOG 2
273.00
54.4
44.4
*
*
SUBWOOFER 273.00
54.4
44.4 * *
COAXIAL 273.00
54.4
44.4
* *
VIDEO 273.00
54.4
44.4
*
*
IR IN
273.00
54.4
44.4
*
*
TRIGGER OUT
273.00
54.4
44.4
*
*
HDMI IN/OUT
273.00
54.4
44.4
*
*
SPEAKER
273.00
54.4 44.4 20.2 14.1
AC
POWER
CORD 273.00
54.4 44.4 23.6 18.3
*: less than 25 ㏈㎺
Limit
according
to
EN55013:2001+A2(2006)