AMPLIFIER SECTION BIAS ADJUSTMENT
Measurement condition
.No input signal or volume position is minimum.
.No input signal or volume position is minimum.
Standard value
.Ideal current = 48mA (± 5%)
.Ideal DC Voltage = 25.92mV (± 5%)
.Ideal current = 48mA (± 5%)
.Ideal DC Voltage = 25.92mV (± 5%)
DC VOLTMETER ; Connect to
CN61(CEN),CN64(SR),CN63(FL),CN65(SBL/SL
NO.
1
2
3
2
3
Surround Left
Surround Right
4
5
5
Channel
Front Left
Front Right
Center
CN64
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
25.92mV (± 5%)
CN62
CN61
CN65
CN61
CN65
Adjust for
Adjustment
25.92mV (± 5%)
CN63
CN61
CN64
CN63
CN65
CN62
+
-
DC EVM
CUP12026* (MAIN PCB)
(AVR154, 155)),CN62(FR)
VR82
VR83
VR84
VR85
VR86