Read Harman Kardon AVR 151 (serv.man3) EMC - CB Certificate online
Reference No. : 54121302C Page 7/45
◀ Anam EMC Test Laboratory ▶
5.4. Test instrument
Equipment
Manufacturer
Type No.
Serial No.
Test site
Shielded room
-
-
Measurement
Receiver
Receiver
R & S
ESCI
100348
Artificial mains
Network
Network
R & S
ESH3-Z5
844249/020
EMCO 3825/2 90101718
Test Compact Disc
Abex
TCD-782
N/A
R. C. Oscillator
Kenwood
AG-203A
3090241
Signal Generator
Anritsu
MG3632A
MT79870
* R & S: Rohde & Schwarz
5.5. Test protocol
Date: January 28, 2013
Grounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A.
report as Annex A.
Mode
Freq.
(㎒)
Quasi-peak (㏈㎶) Average
(㏈㎶)
Limit
Disturbance value
Limit
Disturbance value
Line 1
Line 2
Line 1
Line 2
Tuner .150 66.0 61.7 61.4 56.0 43.2 43.1
Ungrounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A
report as Annex A
Mode
Freq.
(㎒)
Quasi-peak (㏈㎶) Average
(㏈㎶)
Limit
Disturbance value
Limit
Disturbance value
Line 1
Line 2
Line 1
Line 2
Tuner .150 66.0 57.9 58.1 56.0 38.7 38.1
USB .150 66.0 56.2 56.4 56.0 37.8 39.4
The equipment does comply with the requirements.
For the measurement data, see Annex A (6 Copies).