Reference No. : 54121302C                                                                                                                  Page 6/45
 
◀  Anam EMC Test Laboratory  ▶
 
 
5. MAINS TERMINAL DISTURBANCE VOLTAGE IN THE FREQUENCY 
RANGE 0.15MHz TO 30MHz
 
 
   5.1. Operating environment 
Temperature 
: 17℃ 
Relative humidity  : 41 % 
 
5.2. Test set-up and procedure 
 
 
 
The mains terminal disturbance voltage was measured with the EUT in a 
Screened room. The EUT was placed on a non-metallic table by 0.8m above   
the metallic grounded floor and 0.4m from the reference ground panel (RGP) 
wall. The distance to other metallic surfaces was at least 0.8m. 
The EUT was tested with the outer conductor of the antenna input connected 
as well as not connected to the ground terminal of the AMN. 
The level of the test signal was 500mV (1 KHz) at coaxial RF input connector. 
Amplitude measurements were performed with a quasi-peak detector and, 
If required, with an average detector. 
 
5.3. Measurement uncertainty 
 
Mains terminal disturbance voltage, quasi-peak detection:  ±2.0dB 
 
Mains terminal disturbance voltage, average detection      :  ±2.0dB 
 
The measurement uncertainty describes the overall uncertainty of the given 
 
measured value during the operation of the EUT in the above-mentioned way. 
 
 
 
 
 
 