Read Harman Kardon AVR 151 (serv.man3) EMC - CB Certificate online
Reference No. : 54121302C Page 15/45
◀ Anam EMC Test Laboratory ▶
Note:1) The spectrum was checked from 30 to 300 ㎒.
2) The cable (6.0m length) loss is included in a correction factor.
3) Detector function of the measuring instrument:
QP: Quasi-peak, AV: Average
4) QP line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 43.9
AV line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 33.9
5) *: Less than 25 ㏈㎺
For the measurement data, see Annex C (11 Copies)
9. HARMONICS
9.1. Operating environment
Temperature
: 21℃
Relative humidity : 38%
9.2. Test set-up and procedure
Harmonics of the fundamental current were measured up to 2 ㎑ using a
universal power analyzer. The measurement was carried out under steady
conditions and using averaging.
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2(2006)
The measurement was performed with the Test software for Windows
The input signal and load conditions were set as given in clause C.3
The input signal and load conditions were set as given in clause C.3
9.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
R. C. Oscillator
Kenwood
AG-203A
3090241
Universal power analyzer Voltech
PM6000
100006700178
Test Compact Disc
Abex
TCD-782
N/A
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
9.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex C (3 Copies).
For the measurement data, see Annex C (3 Copies).