Reference No. : 54121302C                                                                                                                  Page 15/45
 
◀  Anam EMC Test Laboratory  ▶
 
 
Note:1) The spectrum was checked from 30 to 300 ㎒. 
 
     2) The cable (6.0m length) loss is included in a correction factor. 
 
     3) Detector function of the measuring instrument:  
 
 
QP: Quasi-peak, AV: Average 
 
     4) QP line: Limit (㏈㎺) = Frequency (㎒)  ×0.037 + 43.9 
 
              AV line: Limit (㏈㎺) = Frequency (㎒)  ×0.037 + 33.9 
 
     5) *: Less than 25 ㏈㎺ 
 
For the measurement data, see Annex C (11 Copies)   
 
9. HARMONICS 
     
9.1. Operating environment 
Temperature 
: 21℃ 
Relative humidity  : 38% 
 
    9.2. Test set-up and procedure 
 
Harmonics of the fundamental current were measured up to 2 ㎑ using a 
 
universal power analyzer. The measurement was carried out under steady   
 
conditions and using averaging. 
 
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2(2006) 
 
The measurement was performed with the Test software for Windows 
The input signal and load conditions were set as given in clause C.3 
 
   9.3. Test instrumentation 
Equipment 
Mfr. 
Type No. 
Serial No. 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
Universal power analyzer  Voltech 
PM6000 
100006700178 
Test Compact Disc 
Abex 
TCD-782 
N/A 
Programmable controller 
Pacific 
360AMXT/UPC32 
151 
Magnetics module 
Pacific 
134310 
334 
 
9.4. Test result 
 
The equipment does comply with the requirements. 