AVR 139 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 8

Read Harman Kardon AVR 139 EMC - CB Certificate online

Reference No. : 54120903C                                                                                                                Page 7/60
 
◀  Anam EMC Test Laboratory  ▶
 
 
5.4. Test instrument 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Test site 
Shielded room 
Measurement 
                      Receiver 
R & S 
ESCI 
100348 
R & S 
ESH3-Z5 
844249/020 
Artificial mains 
                      Network  EMCO 3825/2 90101718 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
 
* R & S: Rohde & Schwarz 
 
5.5. Test protocol 
 
 
Date: March 25, 2009 
 
Grounded at the Signal GND Terminal on the Rear Enclosure. 
 
An overview sweep performed with peak detector is included in the test 
report as Annex A. 
Quasi-peak (㏈㎶) Average 
(㏈㎶) 
Disturbance value 
Disturbance value 
Mode 
Freq. 
(㎒) 
Limit 
Line 1 
Line 2 
Limit 
Line 1 
Line 2 
Tuner .15  66.0 47.3 47.1 56.0 26.6 25.7 
 
 
 
 
 
 
 
 
 
 
Ungrounded at the Signal GND Terminal on the Rear Enclosure. 
 
An overview sweep performed with peak detector is included in the test 
report as Annex A 
Quasi-peak (㏈㎶) Average 
(㏈㎶) 
Disturbance value 
Disturbance value 
Mode 
Freq. 
(㎒) 
Limit 
Line 1 
Line 2 
Limit 
Line 1 
Line 2 
Tuner .15  66.0 38.5 38.8 56.0 11.2 11.4 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CD .15 66.0 34.8 34.5 56.0 9.8 8.7 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The equipment does comply with the requirements. 
 
For the measurement data, see Annex A (6 Copies). 
 
 
 
 
Page of 108
Display