Ref No.
Cause and Remedy
Symptom
1. µ-COM I.C B+( 3.3 )V check.
2. REMOCON data check.
I.C NO. (101) / I.C Pin No. ( 62)
FM Failure.
A) FM MUTE adjustment inferior.
B) FRONT-END inferior.
C) FM DET COIL inferior.
D) PLL&MPX IC check.
1. PLL&MPX  I.C B+( 5 )V,B+( 3.3 )V check.
I.C NO. (1 ) / I.C Pin No. ( 8,21 )
2. PLL control data check. (Data/CE/Clock)
E) TUNER B+ voltage inferior.
F) µ-COM I.C & Resonator inferior.
I.C No. ( 101 )
1. µ-COM I.C B+( 3.3 )V check.
2.  Micom control data check.
I.C Pin No. ( 20,23,24,60,61)
AM Failure.
A)  PLL&MPX IC check.
1. PLL&MPX  I.C B+( 5 )V,B+( 3.3 )V check.
I.C NO. (1 ) / I.C Pin No. ( 8,21 )
2. PLL control data check (Data/CE/Clock)
B) TUNER  B+ voltage inferior.
C) AM OSC COIL inferior.
D) µ-COM I.C & Resonator inferior.
I.C No. (101 )
1. µ-COM I.C B+( 3.3)V check.
2.  Micom control data check.
I.C Pin No. ( 20,23,24,60,61)
Stereo Effect Failure.
A) FM DET COIL Inferior.
Stereo does not light up. 
B)  PLL&MPX IC check.
1. PLL&MPX  I.C B+( 5 )V,B+( 3.3 )V check.
2. MPX control data check.
C) µ-COM I.C & Resonator inferior.
I.C No. ( 101 )
1. µ-COM IC B+( 3.3)V check 
2.  Micom control data check.
I.C Pin No. ( 20,23,24,60,61)
Tuner Sound Dead.
A) Connector's disconnection or disjunction. 
 1. "L / R" Channel dead.
Change or Close insertion of the connector.
 2. "LEFT" Channel dead.
B) FM DET COIL inferior.
 3. "RIGHT" Channel dead.
C) AM IFT COIL inferior.
D) PLL&MPX IC check.
1. Signal IN/OUT terminal.
2. I.C driving voltage check. ( +5V,+3V3 ) 
I.C NO. (1 ) / I.C Pin No. ( 8,21 )