AVR 132 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 11

Read Harman Kardon AVR 132 (serv.man2) EMC - CB Certificate online

 
 
- Page 5 of 32 - 
 
 
www.nemko.com
 
Report No.  70635 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
3 GENERAL 
REQUIREMENTS 
 
 
Safety class of the apparatus ................................. :
Class II 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 Ventilation 
instructions 
require the use of the test 
box 
No test box required. Tested 
according to manufacturers 
instructions 
 
5 MARKING 
 
 
Comprehensible and easily discernible 
On front and rear side of the 
enclosure
 
 
Permanent durability against water and petroleum 
spirit 
Tested with water / spirit 
5.1 Identification, 
maker, model ................................... :
Brand: Harman / Kardon 
Model: AVR132/230. 
See also copy of marking plate 
 
Class II symbol if applicable 
Class II symbol is applied in 
according to IEC 60417-5172. 
 
Rated supply voltage and symbol .......................... :
AC-symbol ( 
~
 ) with 230V  
marked 
 
Frequency if safety dependant 
50Hz 
 
Rated current or power consumption ..................... :
235W 
5.2 Earth 
terminal 
Class II apparatus 
 
Hazardous live terminals 
No hazardous live terminals 
 
Supply output terminals (other than mains) 
No socket outlet for providing 
power to other apparatus.
 
5.3 
Use of triangle with exclamation mark 
Correct symbol applied: 
Imprinted on rear side in 
connection with CAUTION of 
opening. Further; no incorrect 
use of this symbol is found.
 
5.4 
Instructions for use 
User information in the 
following language: English. 
See comments in Summary of 
Testing. 
TRF No:  IEC/EN 60065F 
Page of 49
Display