Report No.: EM201300550-11                        Application No.:
 
ZJ00032797                   Page 9 of 45 
4. EMISSION TEST  
4.1 CONDUCTED EMISSION MEASUREMENT 
4.1.1 LIMITS 
Frequency (MHz) 
Quasi-peakdBμV) 
AveragedBμV 
0.15 ~ 0.5 
66~56 56~46 
0.5 ~ 5 
56 46 
5 ~ 30 
60 50 
NOTE
(1) The lower limit shall apply at the transition frequencies. 
(2) The limit decreases in line with the logarithm of the frequency in the range of  0.15 ~0.5 MHz. 
4.1.2 TEST PROCEDURES 
Procedure of Preliminary Test 
For measurement of the disturbance voltage the equipment under test (EUT) is connected to 
the power supply mains and any other extended network via one or more artificial network(s). 
An EUT, whether intended to be grounded or not, and which is to be used on a table is 
configured as follows: 
–   Either the bottom or the rear of the EUT shall be at a controlled distance of 40 cm from a 
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It 
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as 
follows: 
1)  place the EUT on a table of non-conducting material which is at least 80 cm high. Place the 
EUT so that it is 40 cm from the wall of the shielded room, or 
2)  place the EUT on a table of non-conducting material which is 40 cm high so that the 
bottom of the EUT is 40 cm above the ground plane; 
–    All other conductive surfaces of the EUT shall be at least 80 cm from the reference ground 
plane; 
–    The ANs are placed on the floor that one side of the AN housings is 40 cm from the 
vertical reference ground plane and other metallic parts; 
–    Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded 
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle 
between the ground plane and the table. 
–    I/O cables that are connected to a peripheral shall be bundled in the centre. The end of the 
cable may be terminated if required using correct terminating impedance. The total length 
shall not exceed 1 m. 
The test mode(s) described in Item 2.4 were scanned during the preliminary test. After the 
preliminary scan, we found the test mode described in Item 2.4 producing the highest 
emission level. The EUT configuration and cable configuration of the above highest emission 
levels were recorded for reference of the final test. 
Procedure of Final Test  
EUT and support equipment were set up on the test bench as per the configuration with 
highest emission level in the preliminary test. A scan was taken on both power lines, 
Page of 45