AURA (serv.man7) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 8

Read Harman Kardon AURA (serv.man7) EMC - CB Certificate online

Report No.: EM201300550-10                     Application No.: ZJ00032797                     Page 8 of 13 
 
 
3.2.2 TEST SETUP
 
 
3.2.3 TEST RESULTS 
For GFSK 
Operating Mode with Modulation 
Frequency 
EIRP Level  
(dBm) 
EIRP Level  
(mW) 
2402MHz 
6.94 
9.98 
2441MHz 
6.09 
9.13 
2480MHz 5.18 
8.22 
Test conclusion: 
According this requirement the SAR-measurement has not to be conducted when the 
sending level is < 20 mW. 
 
For 8DPSK 
Operating Mode with Modulation 
Frequency 
EIRP Level  
(dBm) 
EIRP Level  
(mW) 
2402MHz 5.33 
8.37 
2441MHz 4.52 
7.56 
2480MHz 3.41 
6.45 
Test conclusion: 
According this requirement the SAR-measurement has not to be conducted when the 
sending level is < 20 mW. 
EUT
Ground Plane
 
3 m
1.5
m
Cable
Test table & Turntable 
 
1m~4m 
 
EMI 
Receiver 
Page of 13