Report No.: EM201300550-14        Application No.:
 
ZJ00032797        Page 16 of 58 
 
4.2 FREQUENCY RANGE 
4.2.1 LIMITS 
EN300 328 clause 4.3.3 
fL > 2,4 GHz and fH < 2,4835 GHz 
4.2.2 TEST PROCEDURE 
Test EUT in normal conditions, and then repeat in extreme conditions. 
Measurement RBW = 100 kHz, VBW ≥ 100 kHz, average mode with 60 second sweeps selected. 
Pre-test the 3 modulation to find GFSK and 8DPSK is worse case, so only record GFSK and 
8DPSK test data. 
 
4.2.3 TEST SETUP 
 
 
 
 
 
 
 
4.2.4 TEST RESULTS 
Measurement Conditions 
Frequency spot with 
level ≤ -30dBm/100KHz
Limit (MHz) 
Temperature(°C) Voltage 
 
FL 
FH 
Lower 
Higher 
For GFSK 
AC Power 
25 
Vnom 
2400.65 2481.01 
FL>2400.0   FH< 2483.5 
Vmin 
2400.64 2480.93 
Vmax 
2400.76 2481.15 
+70 
Vmin 
2400.62 2480.91 
Vmax 
2400.73 2480.98 
For 8DPSK 
AC Power 
25 
Vnom 
2400.40 2481.59  FL>2400.0 
 
FH< 
2483.5 
               
Antenna  
 
EUT
   
   
Receiver 
Page of 58